Sign In | Join Free | My futurenowinc.com
China ShenzhenYijiajie Electronic Co., Ltd. logo
ShenzhenYijiajie Electronic Co., Ltd.
The company advocates the corporate culture of "integrity and dedication, pragmatic innovation, unity and cooperation, diligence and progress", pays attention to standardized management, advocates
Verified Supplier

4 Years

Home > Gas Sensor >

MQ136 MQ-136 Gas Sensor For Hydrogen Sulfide Gas Leakage Alarms

ShenzhenYijiajie Electronic Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

MQ136 MQ-136 Gas Sensor For Hydrogen Sulfide Gas Leakage Alarms

Model Number : MQ136 MQ-136

Place of Origin : CN

MOQ : 1PCS

Price : Negotiable

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 5000PCS

Delivery Time : 5-8 work days

Packaging Details : Standard packaging

Heater Voltage (Vh) : 5.0V ± 0.1V (AC or DC)

Loop Voltage (Vc) : 5.0V ± 0.1V (DC)

Heater Resistance (Rh) : 30Ω ± 3Ω

Heater Power Consumption (Ph) : ≤ 900mW

Contact Now

MQ136 Gas Sensor For Hydrogen Sulfide Gas Leakage Alarms

Working Principle:

The MQ136 operates based on the principle of gas adsorption on the surface of a semiconductor material. When the target gas (especially H₂S) comes into contact with the heated SnO₂ sensitive layer, the conductivity of the material changes. This change in conductivity is proportional to the concentration of the target gas, which can be converted into a measurable electrical signal through a simple circuit.

Key Features:

  • High sensitivity to hydrogen sulfide (H₂S)
  • Good selectivity for sulfide gases
  • Fast response and recovery times
  • Stable performance and long service life
  • Simple driving circuit requirements
  • Low cost and easy to integrate into detection systems

Applications:

  • Hydrogen sulfide gas leakage alarms
  • Industrial waste gas monitoring (especially in chemical, petroleum, and sewage treatment industries)
  • Portable gas detectors for H₂S
  • Indoor air quality monitoring in specific environments
  • Mining safety equipment for sulfide gas detection

Parameter

Symbol

Value

Unit

Remarks

Heater Voltage Vh 5.0V ± 0.1V - AC or DC
Loop Voltage Vc 5.0V ± 0.1V - DC
Heater Resistance Rh 30Ω ± 3Ω - At room temperature
Heater Power Consumption Ph ≤ 900 mW -
Detection Range - 10 - 1000 ppm For H₂S
Sensitivity S Rs (in air) / Rs (in 100ppm H₂S) ≥ 5 - -
Response Time T90 ≤ 10 s -
Recovery Time T10 ≤ 30 s -
Operating Temperature - -10 - 50 -
Storage Temperature - -20 - 70 -
Relative Humidity - ≤ 95 % RH Non-condensing
Pre-heat Time - ≥ 48 hours For stable performance
Service Life - ≥ 5 years -

MQ136 MQ-136 Gas Sensor For Hydrogen Sulfide Gas Leakage Alarms


Product Tags:

MQ136 hydrogen sulfide gas sensor

      

gas leakage alarm sensor

      

MQ-136 H2S gas detector

      
Wholesale MQ136 MQ-136 Gas Sensor For Hydrogen Sulfide Gas Leakage Alarms from china suppliers

MQ136 MQ-136 Gas Sensor For Hydrogen Sulfide Gas Leakage Alarms Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: ShenzhenYijiajie Electronic Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)